{"id":45685,"date":"2024-01-04T13:51:04","date_gmt":"2024-01-04T11:51:04","guid":{"rendered":"https:\/\/circutor.com\/?p=45685"},"modified":"2024-01-09T12:38:14","modified_gmt":"2024-01-09T10:38:14","slug":"rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11","status":"publish","type":"post","link":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/","title":{"rendered":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text css=&#8221;.vc_custom_1704368098894{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h2>W\u015br\u00f3d nowych funkcji wyr\u00f3\u017cni\u0107 nale\u017cy usprawnienie instalacji bez konieczno\u015bci przerywania zasilania oraz oszcz\u0119dno\u015bci zwi\u0105zane z instalacj\u0105 urz\u0105dze\u0144 dzi\u0119ki \u0142\u0105czno\u015bci przez Ethernet<\/h2>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Przedstawiamy rozszerzenie gamy analizator\u00f3w parametr\u00f3w sieci CVM-C11, jednego z naszych wzorcowych produkt\u00f3w z rodziny urz\u0105dze\u0144 pomiarowych i steruj\u0105cych. Aktualizacja tej gamy produkt\u00f3w, w kt\u00f3rej sk\u0142ad wesz\u0142y trzy nowe modele, polega na \u0142atwiejszej instalacji, uruchomieniu i komunikacji z systemami zarz\u0105dzania i kontroli Scada.<\/p>\n<p>Nowa forma MC pozwala na instalacj\u0119 analizator\u00f3w sieci w rozdzielniach o ograniczonych rozmiarach. Z drugiej strony model Flex gwarantuje uruchomienie bez konieczno\u015bci zatrzymania zasilania, zar\u00f3wno w nowych instalacjach, jak i tych ju\u017c istniej\u0105cych. Poza tym, model Ethernet umo\u017cliwia po\u0142\u0105czenie z systemem Scada bez konwerter\u00f3w no\u015bnik\u00f3w, co pozwala zmniejszy\u0107 koszty instalacji.<\/p>\n<p>Analizator parametr\u00f3w sieci CVM-C11 jest jednym z najbardziej skonsolidowanych urz\u0105dze\u0144 naszej gamy analizator\u00f3w sieci do monta\u017cu na panelu, zar\u00f3wno na rynku krajowym, jak i mi\u0119dzynarodowym.<\/p>\n<p>W nast\u0119pnym filmie przedstawiamy i obja\u015bniamy zalety naszych nowych modeli analizatora.[\/vc_column_text][vc_video link=&#8221;https:\/\/youtu.be\/WPOr60zjcBs&#8221; css=&#8221;.vc_custom_1698329365204{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text css=&#8221;.vc_custom_1704368217611{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h2>Odkryj nowe modele analizatora CVM-C11<\/h2>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Analizatory sieci CVM-C11 s\u0105 konieczne do zarz\u0105dzania i precyzyjnego zarz\u0105dzania instalacjami elektrycznymi.<\/p>\n<p>Poni\u017cej przedstawiamy ulepszenia zawarte w nowych modelach CVM-C11-MC, CVM-C11-FLEX i CVM-C11-ETH, ju\u017c dost\u0119pnych w naszym katalogu produkt\u00f3w.<\/p>\n<h3>CVM-C11- MC, instalacja na ograniczonej przestrzeni<\/h3>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Analizator sieci CVM-C11-MC zosta\u0142 specjalnie zaprojektowany do u\u017cytku razem z efektywnymi przek\u0142adnikami pr\u0105du MC. Te wydajne przek\u0142adniki wyposa\u017cone s\u0105 w wyj\u015bcie pr\u0105du wt\u00f3rnego o warto\u015bci \u2026\/250mA, maj\u0105 niskie zu\u017cycie energii i mo\u017cna je zainstalowa\u0107 razem z dowolnym urz\u0105dzeniem pomiaru energii elektrycznej.<\/p>\n<p><strong>Wyposa\u017cony w tr\u00f3jfazowe przek\u0142adniki pr\u0105du MC3<\/strong><\/p>\n<p>Przek\u0142adniki pr\u0105du MC3 s\u0105 specjalnie zaprojektowane do ich instalacji w ma\u0142ych przestrzeniach, wykorzystuj\u0105c miejsce nad zabezpieczeniami magnetotermicznymi lub r\u00f3\u017cnicowymi. W ten spos\u00f3b, mo\u017cna je \u0142atwo zainstalowa\u0107 w rozdzielniach o ma\u0142ych wymiarach bez konieczno\u015bci ich powi\u0119kszania.<\/p>\n<p>Do gamy przek\u0142adnik\u00f3w MC3 nale\u017c\u0105 trzy modele dla r\u00f3\u017cnych pr\u0105d\u00f3w znamionowych instalacji.[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;44008&#8243; img_size=&#8221;large&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong>3 r\u00f3\u017cne modele<\/strong><br \/>\n63 A<br \/>\n125 A<br \/>\n250 A[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css=&#8221;.vc_custom_1704368416402{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<strong>Wyposa\u017cony w tr\u00f3jfazowe przek\u0142adniki pr\u0105du MC1<\/strong><\/p>\n<p>Ta gama przek\u0142adnik\u00f3w posiada zakres pomiaru pr\u0105du pierwotnego od 50 do 2000 A. Tak samo jak przek\u0142adniki MC3 dzia\u0142aj\u0105 z pr\u0105dem wt\u00f3rnym 250 mA. Urz\u0105dzenia te pozwalaj\u0105 na zmniejszenie ilo\u015bci produkt\u00f3w, jako \u017ce, ka\u017cda pozycja ma 3 zakresy pomiaru pr\u0105du do wyboru, w zale\u017cno\u015bci od pod\u0142\u0105czonych kabli.[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;44019&#8243; img_size=&#8221;large&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong>Modele od 50 A to 2000 A<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css=&#8221;.vc_custom_1704368492243{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h3>CVM-C11- FLEX, elastyczna instalacja, bez przerw<\/h3>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Analizator sieci <strong>CVM-C11- FLEX<\/strong> idealnie nadaje si\u0119 do tych instalacji, w kt\u00f3rych niemo\u017cliwe jest zatrzymanie dzia\u0142ania. Urz\u0105dzenie wykorzystuje c\u0119gi elastyczne o skali 100 mV\/kA do pr\u0105du nawet 100 000A, przy czym jest kompatybilne z wieloma czujnikami pr\u0105du dost\u0119pnymi na rynku.<\/p>\n<p>Jego elastyczny czujnik pr\u0105du pozwala dokonywa\u0107 pomiar\u00f3w pr\u0105du zmiennego w ka\u017cdej instalacji przy ca\u0142kowitym odrzuceniu sk\u0142adowych (DC), niskim zu\u017cyciu mocy, zale\u017cno\u015bci od temperatury, bardzo dobrej liniowo\u015bci i braku problem\u00f3w z nasyceniem.[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;44038&#8243; img_size=&#8221;large&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong>2 dost\u0119pne modele<\/strong><br \/>\nMFC-FLEX-80 (80 mm \u015brednicy)<br \/>\nMFC-FLEX-125 (125 mm \u015brednicy)[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text css=&#8221;.vc_custom_1704368561210{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h3>CVM-C11- ETH, instalacja bez nadmiernych koszt\u00f3w<\/h3>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Nowy model <strong>CVM-C11-ETH<\/strong> zawiera port komunikacyjny Ethernet z protoko\u0142em Modbus\/TCP i BACnet IP, kt\u00f3ry sprawia, \u017ce analizator jest kompatybilny z ka\u017cdym systemem zarz\u0105dzania energi\u0105 Scada.<\/p>\n<p>Dzi\u0119ki \u0142\u0105czno\u015bci przez IP unikniesz instalacji konwerter\u00f3w no\u015bnik\u00f3w aby pod\u0142\u0105czy\u0107 je do w\u0142asnej sieci LAN. Dzi\u0119ki czemu mo\u017cna wyeliminowa\u0107 nadmierne koszty nabycia i instalacji innego sprz\u0119tu. Model Ethernet jest kompatybilny z ka\u017cdym innym standardowym modelem przek\u0142adnika pr\u0105du z wyj\u015bciem pr\u0105du wt\u00f3rnego (&#8230;\/5A o \u2026\/1A).[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;44027&#8243; img_size=&#8221;large&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][\/vc_column_inner][\/vc_row_inner][vc_btn title=&#8221;Chc\u0119 pobra\u0107 katalog produkt\u00f3w \ud83e\udc6a&#8221; style=&#8221;custom&#8221; custom_background=&#8221;#e40040&#8243; custom_text=&#8221;#ffffff&#8221; link=&#8221;url:https%3A%2F%2Falfresco.circutor.com%2Falfresco%2Fdownload%2Fattach%2Fworkspace%2FSpacesStore%2F2dde14b8-035c-4b7e-bca4-6888a70293c8%2FDP_CVM-C11_PL.pdf%3Fguest%3Dtrue&#8221; css=&#8221;.vc_custom_1704368635920{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text css=&#8221;.vc_custom_1704368846708{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h2>Poznaj funkcje stanowi\u0105ce warto\u015b\u0107 dodan\u0105 analizatora CVM-C11<\/h2>\n<p>[vc_empty_space height=&#8221;15px&#8221;]<\/p>\n<p>Poza przedstawieniem niniejszego rozszerzenia, pragniemy r\u00f3wnie\u017c przypomnie\u0107 g\u0142\u00f3wne konkurencyjne zalety analizator\u00f3w CVM-C11, wsp\u00f3lne dla ca\u0142ej gamy.<\/p>\n<p><strong>Wysoka precyzja pomiaru zmiennych elektrycznych<\/strong><\/p>\n<p>Aby obliczy\u0107 r\u00f3\u017cne zmienne elektryczne konieczny jest rzeczywisty pomiar napi\u0119cia (V) i nat\u0119\u017cenia (A). Na podstawie tych dw\u00f3ch zmiennych mo\u017cna obliczy\u0107 reszt\u0119. Z drugiej strony, mo\u017cliwe jest zapewnienie wysokiej precyzji pomiaru zmiennych, aby zminimalizowa\u0107 b\u0142\u0119dy odczytu. Dlatego, w tej serii skupili\u015bmy nasze wysi\u0142ki aby zaoferowa\u0107 ci najlepsz\u0105 dok\u0142adno\u015b\u0107:<\/p>\n<table cellpadding=\"9\">\n<tbody>\n<tr>\n<td bgcolor=\"#ffebeb\"><strong>Model CVM-C11<\/strong><\/td>\n<td bgcolor=\"#ffebeb\"><strong>ITF<\/strong><\/td>\n<td bgcolor=\"#ffebeb\"><strong>FLEX<\/strong><\/td>\n<td bgcolor=\"#ffebeb\"><strong>MC<\/strong><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffebeb\">Pomiar napi\u0119cia fazy<\/td>\n<td bgcolor=\"#ffebeb\">0.2%<\/td>\n<td bgcolor=\"#ffebeb\">0.2%<\/td>\n<td bgcolor=\"#ffebeb\">0.2%<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffebeb\">Pomiar napi\u0119cia fazy<\/td>\n<td bgcolor=\"#ffebeb\">0.2%<\/td>\n<td bgcolor=\"#ffebeb\">2%<\/td>\n<td bgcolor=\"#ffebeb\">0.2%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Pomiar nat\u0119\u017cenia w przewodzie neutralnym<\/strong><\/p>\n<p>Przep\u0142yw pr\u0105du w przewodzie neutralnym mo\u017ce powodowa\u0107 problemy w twojej instalacji takie jak przegrzanie, przepi\u0119cia lub nawet uszkodzenia urz\u0105dze\u0144 ze wzgl\u0119du na utrat\u0119 izolacji. Pomiar pr\u0105du w przewodzie neutralnym pozwala zapewni\u0107 ci\u0105g\u0142o\u015b\u0107 dzia\u0142ania instalacji i zidentyfikowa\u0107 odbiorniki, kt\u00f3re wywo\u0142uj\u0105 te przep\u0142ywy.<\/p>\n<p><strong>Wej\u015bcia i wyj\u015bcia do zarz\u0105dzania odbiornikami i urz\u0105dzeniami<\/strong><\/p>\n<p>Analizator CVM-C11 wykorzystuje wyj\u015bcia cyfrowe do sterowania stanami (otwarty\/zamkni\u0119ty), do zmiany taryfy (a\u017c 3 taryfy i system podw\u00f3jnego zasilania) lub do synchronizacji maksymetru z twoim licznikiem rozliczeniowym.<\/p>\n<p>Poprzez wyj\u015bcia cyfrowe lub przeka\u017anikowe, mo\u017cna skonfigurowa\u0107 alarmy w zale\u017cno\u015bci od stanu dowolnej chwilowej zmiennej elektrycznej. Ponadto, mo\u017cna r\u00f3wnie\u017c u\u017cy\u0107 wyj\u015b\u0107 cyfrowych do wysy\u0142ania impuls\u00f3w proporcjonalnych dla ka\u017cdej zmiennej wzrostowej (energii, koszt\u00f3w) do koncentratora impuls\u00f3w.<\/p>\n<p><strong>Dwa protoko\u0142y komunikacyjne na tym samym urz\u0105dzeniu<\/strong><\/p>\n<p>Wszystkie nasze modele wyposa\u017cone s\u0105 w protok\u00f3\u0142 Modbus i BACnet. Ta funkcja pozwala na wybranie protoko\u0142u zgodnie z rodzajem software, z kt\u00f3rego korzysta twoja instalacja. Ponadto fakt, \u017ce wyb\u00f3r protoko\u0142u jest ca\u0142kowicie konfigurowalny, pozwoli na ujednolicenie twoich produkt\u00f3w pod jednym numerem referencyjnym.<\/p>\n<p><strong>Spersonalizowany ekran<\/strong><\/p>\n<p>Rozumiemy, \u017ce potrzeby klient\u00f3w r\u00f3\u017cni\u0105 si\u0119 wzgl\u0119dem ka\u017cdej instalacji lub mierzonego obci\u0105\u017cenia. Dlatego CVM-C11 pozwala wybra\u0107, kt\u00f3re zmienne chcesz widzie\u0107 na g\u0142\u00f3wnym ekranie, aby wy\u015bwietla\u0107 tylko dane, kt\u00f3ra najbardziej ci\u0119 interesuj\u0105. Zaprojektowali\u015bmy ekran pocz\u0105tkowy, na kt\u00f3rym wy\u015bwietlane s\u0105 najwa\u017cniejsze informacje, aby\u015b m\u00f3g\u0142 szybko sprawdzi\u0107 stan swojej instalacji.[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1704796688330{margin-top: 20px !important;margin-bottom: 20px !important;padding-top: 20px !important;padding-right: 20px !important;padding-bottom: 20px !important;padding-left: 20px !important;background-color: #f3f4f5 !important;}&#8221;]Ten rozw\u00f3j gamy CVM-C11 pozwala na zarz\u0105dzanie zu\u017cyciem i zmiennymi energetycznymi w instalacji ka\u017cdego typu, w spos\u00f3b \u0142atwy i przyjazny dla u\u017cytkownika, zar\u00f3wno bezpo\u015brednio z konfigurowalnego ekranu lub za pomoc\u0105 w\u0142asnej aplikacji Scada.<\/p>\n<p><strong><a href=\"https:\/\/circutor.com\/pl\/produkty\/przyrzady-pomiarowe-i-kontrolne\/stale-analizatory-sieciowe\/stale-analizatory-sieciowe\/\" target=\"_blank\" rel=\"noopener\">Znajd\u017a przek\u0142adnik pr\u0105du, kt\u00f3ry najbardziej pasuje do twojej instalacji \ud83e\udc6a<\/a><\/strong><\/p>\n<p><strong><a href=\"https:\/\/circutor.com\/pl\/produkty\/przyrzady-pomiarowe-i-kontrolne\/przekladniki-i-boczniki-pomiarowe\/transformatory-pradu-przemiennego\/\" target=\"_blank\" rel=\"noopener\">Wi\u0119cej informacji na temat analizator\u00f3w pod poni\u017cszym linkiem \ud83e\udc6a<\/a><\/strong>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text css=&#8221;.vc_custom_1704368098894{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;] W\u015br\u00f3d nowych funkcji wyr\u00f3\u017cni\u0107 nale\u017cy usprawnienie instalacji bez konieczno\u015bci przerywania zasilania oraz oszcz\u0119dno\u015bci zwi\u0105zane z instalacj\u0105 urz\u0105dze\u0144 dzi\u0119ki \u0142\u0105czno\u015bci przez Ethernet [vc_empty_space height=&#8221;15px&#8221;] Przedstawiamy rozszerzenie gamy analizator\u00f3w parametr\u00f3w sieci CVM-C11, jednego z naszych wzorcowych produkt\u00f3w z rodziny urz\u0105dze\u0144 pomiarowych i steruj\u0105cych. Aktualizacja tej gamy produkt\u00f3w, w kt\u00f3rej sk\u0142ad wesz\u0142y [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":44095,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"categories":[3524],"tags":[3598,3593],"class_list":["post-45685","post","type-post","status-publish","format-standard","hentry","category-artykuly","tag-analizy-instalacje","tag-oszczednosc-energii"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11<\/title>\n<meta name=\"description\" content=\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\" \/>\n<meta property=\"og:description\" content=\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\" \/>\n<meta property=\"og:url\" content=\"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-04T11:51:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-09T10:38:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Circutor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Napisane przez\" \/>\n\t<meta name=\"twitter:data1\" content=\"Circutor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/\"},\"author\":{\"name\":\"Circutor\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#\\\/schema\\\/person\\\/9216eaf78015cd0abb5ac95453b110ce\"},\"headline\":\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\",\"datePublished\":\"2024-01-04T11:51:04+00:00\",\"dateModified\":\"2024-01-09T10:38:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/\"},\"wordCount\":1470,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/desarrollo.circutor.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/art-CVM-C11-2.jpg\",\"keywords\":[\"Analizy Instalacje\",\"Oszcz\u0119dno\u015b\u0107 energii\"],\"articleSection\":[\"Artyku\u0142y\"],\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/\",\"url\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/\",\"name\":\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/desarrollo.circutor.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/art-CVM-C11-2.jpg\",\"datePublished\":\"2024-01-04T11:51:04+00:00\",\"dateModified\":\"2024-01-09T10:38:14+00:00\",\"description\":\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#primaryimage\",\"url\":\"https:\\\/\\\/desarrollo.circutor.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/art-CVM-C11-2.jpg\",\"contentUrl\":\"https:\\\/\\\/desarrollo.circutor.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/art-CVM-C11-2.jpg\",\"width\":1920,\"height\":1080,\"caption\":\"CVM-C11\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/artykuly\\\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/desarrollo.circutor.com\\\/pl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#website\",\"url\":\"https:\\\/\\\/desarrollo.circutor.com\\\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/desarrollo.circutor.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\\\/\\\/desarrollo.circutor.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/circutor.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\\\/\\\/circutor.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/CIRCUTOR.ES\",\"https:\\\/\\\/x.com\\\/circutor\",\"https:\\\/\\\/www.instagram.com\\\/circutor_es\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/circutor\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/CIRCUTORoficial\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/desarrollo.circutor.com\\\/#\\\/schema\\\/person\\\/9216eaf78015cd0abb5ac95453b110ce\",\"name\":\"Circutor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/circutor.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/usuario-logo-gris-96x96.png\",\"url\":\"https:\\\/\\\/circutor.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\\\/\\\/circutor.com\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/usuario-logo-gris-96x96.png\",\"caption\":\"Circutor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","description":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"pl_PL","og_type":"article","og_title":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","og_description":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","og_url":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2024-01-04T11:51:04+00:00","article_modified_time":"2024-01-09T10:38:14+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg","type":"image\/jpeg"}],"author":"Circutor","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"Napisane przez":"Circutor","Szacowany czas czytania":"7 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#article","isPartOf":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/"},"author":{"name":"Circutor","@id":"https:\/\/desarrollo.circutor.com\/#\/schema\/person\/9216eaf78015cd0abb5ac95453b110ce"},"headline":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","datePublished":"2024-01-04T11:51:04+00:00","dateModified":"2024-01-09T10:38:14+00:00","mainEntityOfPage":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/"},"wordCount":1470,"commentCount":0,"publisher":{"@id":"https:\/\/desarrollo.circutor.com\/#organization"},"image":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#primaryimage"},"thumbnailUrl":"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg","keywords":["Analizy Instalacje","Oszcz\u0119dno\u015b\u0107 energii"],"articleSection":["Artyku\u0142y"],"inLanguage":"pl-PL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/","url":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/","name":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","isPartOf":{"@id":"https:\/\/desarrollo.circutor.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#primaryimage"},"image":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#primaryimage"},"thumbnailUrl":"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg","datePublished":"2024-01-04T11:51:04+00:00","dateModified":"2024-01-09T10:38:14+00:00","description":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11","breadcrumb":{"@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#primaryimage","url":"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg","contentUrl":"https:\/\/desarrollo.circutor.com\/wp-content\/uploads\/2023\/10\/art-CVM-C11-2.jpg","width":1920,"height":1080,"caption":"CVM-C11"},{"@type":"BreadcrumbList","@id":"https:\/\/desarrollo.circutor.com\/pl\/artykuly\/rozbudowujemy-game-analizatorow-parametrow-sieci-cvm-c11\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/desarrollo.circutor.com\/pl\/"},{"@type":"ListItem","position":2,"name":"Rozbudowujemy gam\u0119 analizator\u00f3w parametr\u00f3w sieci CVM-C11"}]},{"@type":"WebSite","@id":"https:\/\/desarrollo.circutor.com\/#website","url":"https:\/\/desarrollo.circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/desarrollo.circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/desarrollo.circutor.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/desarrollo.circutor.com\/#organization","name":"Circutor","url":"https:\/\/desarrollo.circutor.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/desarrollo.circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/desarrollo.circutor.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/x.com\/circutor","https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial"]},{"@type":"Person","@id":"https:\/\/desarrollo.circutor.com\/#\/schema\/person\/9216eaf78015cd0abb5ac95453b110ce","name":"Circutor","image":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"Circutor"}}]}},"_links":{"self":[{"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/posts\/45685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/comments?post=45685"}],"version-history":[{"count":0,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/posts\/45685\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/media\/44095"}],"wp:attachment":[{"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/media?parent=45685"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/categories?post=45685"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/desarrollo.circutor.com\/pl\/wp-json\/wp\/v2\/tags?post=45685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}