Control module for PV measurement using a shunt

STM-S-24-F915

STM-S-24-F915

Code: E85SE4.DISCONTINUED

  • Communications: LoRa-915 MHz.
  • Digital inputs: 3
  • Measure: 30 A
  • Power supply (Vac): 24 Vdc
  • Mounting: DIN rail

INFORMATION

Applications

Supervision of photovoltaic strings in solar farms and self-consumption installations

SPECIFICATIONS

Mechanical characteristics
Weight (kg)
0,835
Envelope
Self-extinguishing V0 plastic
Fastening
DIN rail
Size (mm) width x height x depth
362 x 114 x 94.5 (mm)
DC power supply
Nominal voltage
24 V ±10%
Consumption
3.6 W
Installation category
CAT II 1500 V
Voltage measurement circuit
Voltage measuring range
-25 ... -1500 Vdc
Input impedance
2400 kΩ
Minimum measurement voltage (Vstart)
-25 V
Installation category
CAT II 1500 V
Maximum input voltage consumption
0,625 mA
Current measurement circuit
Phase current measuring range
0.1 ... 30 A DC
Minimum current measurement
0.1 A
Impedance
0.5 mΩ
Consumption
1 Chanel: 1.0125 W
Installation category
CAT II 1500 V
Digital inputs
Quantity
3
Type
Potential free contact
Input/output insulation
Optoisolated
Maximum short-circuit current
3.2 mA
Maximum open circuit voltage
24 V
User interface
LED
4
Environmental characteristics
Operating temperature
-25...+70 ºC
Storage temperature
-25...+80 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 00
Installation, location, position.
3000 m
Input
Type
Pt100/1000
Range
-30 … 100ºC
Resolution
±0,1 mA
Accuracy
± 3ºC
Standards
Standards
EN 61000-6-2, EN 61000-6-4, EN 61010-1, EN 61010-2-30
Electrical safety, Installation category
Protection against electric shock: Double class II insulation
Electrical safety, Maximum height (m)
3000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

User's manual
3D
Dimensions
Diagram connection
Datasheet
Presentation
Leaflet

ACCESORIES




This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.