Power quality analyzers

CVM-A1611-ITF

CVM-A1611-ITF, Class A power quality analyzer according to IEC61000-4-30 (Ed.3) and IEC62586-2 method

Code: M57111.COMING SOON

  • Certification: IEC 61000-4-30
  • Communications: Ethernet |RS-485 |Wi-Fi
  • Transistor output: 6
  • Nº relays: 2
  • Digital inputs: 6
  • Power supply: 100…300 Vac/Vdc
  • Input current: .../5 A | .../1 A | 250 mA
  • Mounting: Pannel

INFORMATION

Description

The CVM‑A1600 is a high-performance power quality analyzer designed for monitoring and recording quality in medium- and low-voltage installations. In addition to measuring, calculating, recording, and displaying the main electrical parameters, it logs power quality events detected in voltage and current along with their waveforms.

Electrical parameters and quality events are measured and calculated in accordance with IEC 61000‑4‑30, 3rd edition, and the device ensures strict compliance with IEC 62586‑2 testing methods.

As a power analyzer, it also calculates electrical efficiency parameters such as active and reactive power, THD (%), TDD (%), harmonics up to the 63rd order, imbalance, crest factor, and other quality parameters such as flicker and the k factor.

Its touchscreen lets you navigate through all configuration and parameter display screens. Instantaneous, historical, and recorded quality event values can all be viewed.

The built-in web server enables remote access to instantaneous and historical parameters, as well as device configuration.

Applications


The primary application of a Class A-certified power quality analyzer according to IEC 61000‑4‑30 is to measure and record voltage and current quality at the installation’s connection point, in order to detect disturbances or quality issues that could cause equipment failures or production downtime.

Its most common use is installation at the company supply boundary point, in distribution boards, or at the main electrical connection of the installation, operating in parallel with the billing meter. It can also be installed for quality control of high-consumption individual loads, such as motors, furnaces, and so on.

All data can be integrated into Energy Management Systems via APIRest, Modbus TCP, or the IEC 61850 protocol.

SPECIFICATIONS

Mechanical characteristics
Weight (kg)
0,95
Envelope
Self-extinguishing UL94-V0 plastic
Fastening
Pannel (DIN43700) 138x138
Size (mm) width x height x depth
201 x 145 x 131 (mm)
AC power supply
Nominal voltage
100 ... 300 V ~
Frequency
47 ... 63 Hz
Consumption
14 … 20 VA
Installation category
CATIII 300 V (2000 m), CATII 300 V (5000 m)
DC power supply
Nominal voltage
100 ... 300 Vdc
Consumption
8,5 … 9 W
Installation category
CATIII 300 V (2000 m), CATII 300 V (5000 m)
Auxiliary battery power supply
Autonomy
20 s
Voltage measurement circuit
Nominal voltage
110 ... 480 Vph-N, 190 … 830 Vph-ph
Voltage measuring range
10 … 600 V~ (Ph-N)
Frequency measuring range
42.5 ... 69 Hz
Input impedance
2 MΩ
Minimum measurement voltage (Vstart)
10 Vph-N, 17 Vph-ph
Installation category
CATIII 600 V (2000 m), CATIII 300 V (5000 m)
Sampling frequency
42.5 ... 69 Hz
Current measurement circuit
Nominal current (In)
…/5A (for IEC61000-4-30), …/1A, …/0,250A
Phase current measuring range
0.01…6A (…/5 A) IEC61000-4-30, 0.01…12 A (…/1 A), 0.01…0.3 A (…/0.250 A)
Neutral current measuring range
0.01…6A (…/5A), 0.01…12 A (…/1A), 0.01…0.3 A (…/0.250A)
Maximum pulse current
15A (…/5A)
Minimum current measurement
0,01 A
Maximum input current consumption
0.9 VA
Installation category
CATIII 600 V (2000 m), CATIII 300 V (5000 m)
Measurement accuracy
Phase voltage measurement
± 0.1 % Un (class 0.1) (10% … 150%) Class A IEC61000-4-30
Neutral voltage measurement
± 0.1 % Un (class 0.1) (10% … 150%)
Phase current measurement
0,2% (0,01 ... 10A) (…/5A) Class A IEC 61000-4-30
Neutral current measurement
0,2% (0,01 ... 10A) (…/5A)
Frequency measurement
Class 0,02 (42,5 ... 69 Hz) ±10 mHz IEC61000-4-30
Active power measurement (kW)
Class 0,2 ± 1 digit IEC61557-12
Apparent power measurement (kVA)
Class 0,02 (42,5 ... 69 Hz) ±10mHz IEC61000-4-30
Reactive power measurement (kvar)
Class 0,5 ± 1 digit IEC61557-12
Active energy measurement (kWh)
Class 0,2S IEC62053-22
Reactive energy measurement (kvarh)
Class 0,5S IEC62053-24
Power factor measurement
Class 0,5 IEC61557-12
Voltage THD
Class A IEC61000-4-30 & Class I (IEC61000-4-7) (0,2% .. 100%)
Voltage harmonics (THD)
Class A IEC61000-4-30 & Class I (IEC61000-4-7) ±0,15% (0,08% .. 200%)
Current THD
Class A IEC61000-4-30 & Class I (IEC61000-4-7) (0,2% .. 100%)
Pinst. Flicker
Class A IEC61000-4-30 & Class F1 IEC61000-4-15 (0 .. 10 Pst)
Pst Flicker
Class A IEC61000-4-30 & Class F1 IEC61000-4-15 (0 .. 10 Pst)
Voltage unbalance (Kd)
Class A IEC 61000-4-30 ± 0.15% (0% .. 200%)
Current unbalance (Kd)
Class A IEC 61000-4-30 ± 0.15% (0% .. 200%)
Digital transistor outputs
Quantity
6
Maximum voltage
48 Vdc
Maximum current
130mA
Maximum frequency
1 kHz
Pulse width
1 ms
Pulse output, time period (Ton / Toff)
0,3 ms/0,7 ms
Digital relay outputs
Quantity
2
Nominal voltage
230V~
Maximum open contact voltage
251 V ~ / 30 Vdc
Nominal current
2,5 A
Maximum current
0,3 A
Electrical life (at maximum load)
3x104 cycles
Mechanical life
1x107 cycles
Maximum switching capacity
1500 VA / 180 W
Digital inputs
Quantity
6
Type
Potential-free contact
Input/output insulation
4 kV
Maximum short-circuit current
5 mA
Maximum open circuit voltage
15 Vdc
Serial communication
Technology / Type
RS-485
Protocol
Modbus RTU
Communication Network
Technology / Interface
2 x Ethernet 10BaseT - 100BaseTx
Protocol
HTTPS - NTP - DNS - WSS - SFTP - FTP - IEC61850 - SMTP - ModbusTCP
Connection mechanism
RJ45
User interface
Display type
8" touchscreen
Environmental characteristics
Operating temperature
-20...+65 ºC
Storage temperature
-20… +80 ºC
Relative humidity (without condensation)
5 ... 95%
Protection class
IP 40 (Front), IP 30 (unmounted)
Standards
Standards
UNE-EN 55016-2-1; UNE-EN 55022; UNE-EN 61000-4-2; UNE-EN 61000-4-4; UNE-EN 61000-4-5; UNE-EN 61000-4-6; UNE-EN 61000-4-8; UNE-EN 61000-4-11; UNE-EN 61000-4-20; UNE-EN 61000-4-30; IEC 62586-2; UNE-EN 60068-2-1; UNE-EN 60068-2-2; UNE-EN 60068-2-78; UNE-EN 61010-1; UNE-EN 61010-2-30; UNE-EN 61557-12; EN 18031-1:2024; ETSI EN 301 489-1 V2.2.3; ETSI EN 301 489-17 V3.3.1; ETSI EN 301 489-19 V2.2.1; EN 62311:2008;

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

User's manual
Technical guide
3D
Dimensions
Datasheet
Software & Firmware