Measuring transducers

CFE-AP

CFE-AP, Transducer Hz

Code: M25521.DISCONTINUED

  • Output type: 1
  • Analog output: 0…20mA
  • System: Selecting Network voltage: 115 / 240 / 400 Vac
  • Measure: 45 ...... 55 Hz

INFORMATION

Description

The CFE and CFE-AP transducers, convert input frequency to D.C process indicator signal.

The analog output is directly proportional to the input frequency.

SPECIFICATIONS

Mechanical characteristics
Weight (kg)
0,19
Size (mm) width x height x depth
20 x 70 x 110 (mm)
AC power supply
Nominal voltage
0…5, 10 Vcc
Voltage measurement circuit
Voltage measuring range
70…110 % Vn
Maximum permanent measurement voltage
120 % Vn
Consumption
2,5 VA
Measurement accuracy
Phase current measurement
0,5 % FS
Analogue outputs
Current mode, nominal range
0…10, 20 mAac
Voltage mode: nominal output range
0…5, 10 Vac
Analogue inputs
Load impedance in voltage
> 500 Ω
Load impedance in current
< 500 Ω
Response time
< 300 ms (0…99 % Vn)
Ripple (effective RMS value)
< 1 %
Environmental characteristics
Operating temperature
-10…+60 °C
Storage temperature
-40….+70 °C
Protection class
IP 20 (Terminals) IP 40 (case)
Standards
Standards
IEC 529, IEC 688, IEC 801, EN 50081-1, EN 50082-1, IEC 1010
Electrical safety, Maximum height (m)
2000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

Dimensions
Diagram connection
Datasheet

ACCESORIES